層析柱內徑5mm 10mm 耐壓50bar 耐有機

Chromatography Column, ID 5mm / 10mm , Max Pressure 50 bar, Resistant to Organic Solvent 

清洗

建議:第一次使用時請先清洗玻璃柱管和連接處,以便去除在生產過程中可能殘留的物質???/span>選用常規的洗滌劑或實驗室級去污劑來清洗,我們的玻璃柱管亦可高溫消毒。


Cleaning

Recommendation: Before initial use, please clean the glass column tube and connections to remove any potential residues from the manufacturing process. Conventional detergents or laboratory-grade cleaning agents can be used for cleaning. Our glass column tubes can also be sterilized at high temperatures.


安裝固定端
1、首先要確保玻璃管和固定帽上的螺紋沒有碎片和毛刺以防止安裝時螺紋被損壞。
2、用流動相或適用的溶劑充分潤濕O型-密封圈。

3、輕輕將柱床支撐的固定末端緩慢地垂直推進柱管,并保持整個過程在一條直線完成,一定要避免安裝時有斜角以免損壞密封圈和玻璃管末端。


Installing the Fixed End

1.First, ensure the threads on the glass tube and the fixed end cap are free of debris and burrs to prevent damage during installation.

2.Thoroughly wet the O-ring seal with the mobile phase or a suitable solvent.

3.Gently and slowly insert the fixed end with the column bed support vertically into the column tube, maintaining alignment throughout the process. Avoid any angled insertion to prevent damage to the seal and the end of the glass tube.


填充層析柱
完成以上工序后,現在可以裝填層析填料。由于市面上的填料種類眾多,各品種要求不一,我們推薦您在裝柱時最好按照填料制造商的指導來裝填層析柱。
我們已經預先在柱管上印制了柱床的橫截面積和柱高刻度,以方便您裝填時計算柱床體積和高度。每個刻度間距是10毫米,我們同時也印制了柱管耐受壓力。我們提供的刻度僅作為參考。


Column Packing

After completing the steps above, the column can now be packed with chromatography media. As there are numerous types of media available, each with potentially different requirements, we recommend packing the column according to the media manufacturer's instructions.
We have pre-printed the column bed's cross-sectional area and height markings on the column tube to facilitate the calculation of bed volume and height during packing. The scale intervals are 10 mm. We have also printed the pressure resistance of the column tube. The scales we provide are for reference only.


安裝適配器
1、首先確保玻璃管和固定帽沒有破損。
2、關閉層析柱出口防止柱床干涸。
3、調整柱管中液面至少比柱床高出1-2cm。
4、將適配器上的調節帽和固定帽一起旋到靠近篩板處。
5、 用水充分潤濕O型-密封圈和篩板,并確保篩板中沒有氣泡殘留。
6、 輕輕將適配器垂直推入玻璃管,直到固定帽可以擰到玻璃柱管上,請確保整個操作在一條直線上完成。
7、 將固定帽擰緊后再往回擰15°即可,注意請不要將固定帽擰過緊。
8、 握住固定帽,同時緩慢逆時針旋轉調節帽將適配器上的柱塞調到柱管中需要的位置。

注:通常在使用時柱床高度會略有下降,我們建議裝柱時可將適配器的柱塞調節到略低于柱床沉降后的高度。


Adapter installation

1.First, ensure the glass tube and the fixed end cap are undamaged.

2.Close the column outlet to prevent the column bed from drying out.

3.Adjust the liquid level in the column tube to be at least 1-2 cm above the top of the column bed.

4.Screw the adjustment nut and the fixed cap on the adapter together down close to the frit.

5.Thoroughly wet the O-ring seal and the frit with water, ensuring no air bubbles are trapped in the frit.

6.Gently push the adapter vertically into the glass tube until the fixed cap can be screwed onto the glass column tube. 7.Ensure the entire operation is performed in a straight line.

8.After tightening the fixed cap, unscrew it by approximately 15°. Please avoid over-tightening the fixed cap.

Hold the fixed cap and slowly turn the adjustment nut counterclockwise to lower the adapter plunger to the required position within the column tube.
Note: The bed height often decreases slightly during use. We recommend adjusting the adapter plunger to a position slightly below the settled bed height after packing.



連通層析柱

我們提供的管線上的1/4"-28接頭是專用于連接柱管連接帽的。管線的另一端可自行添加與您層析系統所匹配的接頭。


Column Connecting

The 1/4''-28 fittings on the tubing we supply are specifically designed for connecting to the column tube end cap. You can add a fitting compatible with your chromatography system to the other end of the tubing.


保存層析柱
如要保存空柱,只需用清水沖洗干凈即可,如裝有填料,亦可保存在20%乙醇中。

請避免O型-密封圈上殘留有如IPA這類的有機溶劑,否則其會溶解密封圈,并使其粘連在柱管內壁。


Column Storage

If storing an empty column, simply rinse it thoroughly with clean water. If packed with media, it can also be stored in 20% ethanol.
Avoid leaving organic solvents (such as IPA) on the O-ring seals, as they can dissolve the seals and cause them to stick to the inner wall of the column tube.


注意事項
1、 玻璃管螺紋處相對易被損壞,裝柱時請盡量不要有斜角,并輕輕進行。
2、 O型-密封圈在裝柱時,請充分潤濕,否則會增加其與柱管間摩擦力,造成軸向壓縮困難,更可能導致密封圈損壞。
3、 如需更換篩板,推薦使用我們專門用于篩板拆卸的工具,以免損壞適配器末端。

4、 有時填料或使用的溶劑可能會殘留在 O型密封圈上,導致適配器移動困難,此時可以將層析柱放入冰箱冷藏室數個小時,這樣有助于移動適配器。


Precautions

1.The threaded parts of the glass tube are relatively fragile. During installation, try to avoid angled forces and handle gently.

2.When installing the adapter, ensure the O-ring is thoroughly wetted. Otherwise, friction between the seal and the column tube may increase, making axial compression difficult and potentially damaging the seal.

3.If replacing the frit, we recommend using our specialized tool for frit removal to avoid damaging the adapter end.

4.Sometimes media particles or used solvents may remain on the O-ring, making the adapter difficult to move. Placing the column in a refrigerator for several hours may facilitate adapter movement.


層析柱內徑5mm 10mm 耐壓50bar 耐有機

層析柱內徑5mm 10mm 耐壓50bar 耐有機


 

產品咨詢

留言框

  • 產品:

  • 您的單位:

  • 您的姓名:

  • 聯系電話:

  • 常用郵箱:

  • 省份:

  • 詳細地址:

  • 補充說明:

  • 驗證碼:

    請輸入計算結果(填寫阿拉伯數字),如:三加四=7

聯系我們

上海宸喬生物科技有限公司 公司地址:上海市阿克蘇路1187號516室   技術支持:化工儀器網
  • 聯系人:王經理
  • QQ:3004300903
  • 公司傳真:021-59100893-802
  • 郵箱:sales@keyanwang.com.cn

掃一掃 更多精彩

微信公眾號

網站二維碼

| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |